Re: Pins 3 and 5 resistance at housing terminal Posted by Ari [Email] (#2847) [Profile/Gallery] (more from Ari) on Wed, 9 Feb 2005 09:41:45 In Reply to: Pins 3 and 5 resistance at housing terminal, romick, Wed, 9 Feb 2005 09:17:37 Members do not see ads below this line. - Help Keep This Site Online - Signup |
This is from my TCS manual:
Disconnect throttle housing connector. Check resistance
between throttle housing terminals No. 3 (Blue wire) and No. 5
(Black/White wire). With throttle valve in idle position, about 27
k/ohms should be present. With accelerator depressed one-half way,
about 500 ohms should be present. If resistances are not to
specification, replace throttle housing. If resistances are to
specification, go to next step.
I believe that accelerator is actually throttle position.