yes makes sense, here is what the codes mean Posted by bobc [Email] ![]() ![]() ![]() In Reply to: Re: Front defroster not working...help!, Tom Bucuk, Thu, 3 Jan 2008 15:12:31 Members do not see ads below this line. - Help Keep This Site Online - Signup |
it means you have one code ( the number on the left is the number of faults found), and the code is 14 (the actual codes are on the right)
so, you have this:
14 Stepping motor, air distribution flap - Loose flap
Here is a list of codes and what they mean. I cant remember where I got this from but I saved it!
1 Control module - Internal control module malfunction
2 Cabin temperature sensor - Open circuit or short to B+
2 Cabin temperature sensor - Short-circuit to ground
3 Solar sensor - Open circuit or communication error
4 Mixed-air temperature sensor, LH - Open circuit or short to B+
4 Mixed-air temperature sensor, LH - Short-circuit to ground
5 Mixed-air temperature sensor, RH - Short-circuit to ground
5 Mixed-air temperature sensor, RH - Open circuit or short to B+
6 Stepping motor, air-mixing flap, LH - Open circuit, short to B+ or short
to ground
7 Stepping motor, air-mixing flap, LH - Jammed flap
8 Stepping motor, air-mixing flap, LH - Loose flap
8 Stepping motor, air-mixing flap, RH - Loose flap
9 Stepping motor, air-mixing flap, RH - Open circuit
9 Stepping motor, air-mixing flap, RH - Short-circuit to ground
10 Stepping motor, air-mixing flap, RH - Jammed flap
12 Stepping motor, air distribution flap - Open circuit
12 Stepping motor, air distribution flap - Short-circuit to ground
13 Stepping motor, air distribution flap - Jammed flap
14 Stepping motor, air distribution flap - Loose flap
18 Heat exchanger solenoid - Open circuit, short-circuit to ground
18 Heat exchanger solenoid - Short-circuit to B+
19 Circulation pump - Open circuit, short-circuit to ground
19 Circulation pump - Short-circuit to B+
20 Control voltage, fan - Short-circuit to B+
20 Control voltage, fan - Short-circuit to ground
21 Direct current motor, air recirculation flap - B+ open circuit or shorted to ground
22 This fault code means the ACC software is corrupt, this will require re-flashing by a dealer using tech2 Most ACC systems will work normally with this code.
23 Sensor ground - Ground to sensors shorting to B+
_______________________________________ '08 9⁵ 2.3T SportCombi, Polar White '01 9⁵ Aero Midnight Blue (benched) '00 9⁵ Aero Midnight Blue (rescued) '99 9⁵ Base model, Cosmic blue '00 9⁵ Aero Silver (RIP - transmission )