1979-1993 & 94 Conv [Subscribe to Daily Digest] |
[Main C900 Bulletin Board | BBFAQ |
Next by Date | Post Followup ]
Member Login / Signup - Members see fewer ads. - Latest Member Gallery Photos
Re: 1986 Saab Turbo 16 Valve 900 Radiator Fans Posted by Kevin K [Email] (#374) [Profile/Gallery] (more from Kevin K) on Mon, 24 Jun 2002 16:32:47 In Reply to: 1986 Saab Turbo 16 Valve 900 Radiator Fans, george chiassion, Mon, 24 Jun 2002 14:26:08 Members do not see ads below this line. - Help Keep This Site Online - Signup |
if u blow fuse with no fan relay/jumper installed, just shorting fan-switch wires ..... could be ac loop problem.
try pulling ac compressor relay (see link), and repeat your test. still trouble, test all wiring linkin rad fan and ac compr relay.
xxxxxxxxxxxxxx
to get going with 1 controlled fan:
1) verify fan works with isolated volts and ground, power from relay slot 30.
2) disconnect fan switch wires, toss fan relay, and jump slots 30 and 87, 16ga soldered jumper.
3) verify 12v, key off, at one of fan switch wires. connect that one to switch. make jumper to go from other switch post to the uncoupled fan connector. use bentley to help on wiring. make a ground wire for tha fan.
4) verify by shorting fan switch leads together ... fan on key on or off.
posted by 52.128.3...
No Site Registration is Required to Post - Site Membership is optional (Member Features List), but helps to keep the site online